ALTRONIX CORPORATION UL 12VDC@10A 8OUT AC/BATT SUP W/ENCL
Product Info
ACCESS POWER CONTROLLER PROVIDING A TOTAL OF (8) PTC PROTECTED OUTPUTS INCLUDES (1) POWER SUPPLY/CHARGER WHICH IS 12VDC@10 AMP 115VAC INPUT. GREY ENCLOSURE 15.5?H X 12?W X 4.5?D. ACCOMMODATES UP TO TWO (2) 12VDC/12AH BATTERIES. UL/CUL LISTED (UL294).
Altronix AL1012ULACMCB converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC Fail-Safe and/or Fail-Secure outputs with a total of 10A continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or FailSecure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is indi
Features
Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
Fire Alarm disconnect input options:
a) Normally open (NO) or normally closed (NC) dry contact input.
b) Polarity reversal input from FACP signaling circuit.
Alarm output relay indicates that FACP input is triggered (form “C” contact rated @ 1A 28VDC not evaluated by UL).
Short circuit and thermal overload protection.
Visual Indicators
Red LEDs indicate outputs are triggered (relays energized).
Green LED indicates FACP disconnect is triggered.
AC input and DC output LED indicators.
Battery Charging
Built-in charger for sealed lead acid or gel type batteries.
Automatic switch over to stand-by battery when AC fails.
Zero voltage drop when unit switches over to battery backup (AC failure condition).
Battery fail and battery presence supervision (form “C” contact).
(Batteries are sold separately).
Temperature
Operating: 0ºC to 49ºC (32ºF to 120ºF).
Storage: – 20ºC to 70ºC ( – 4ºF to 158ºF).
Relative Humidity: 85% +/- 5%.
BTU/Hr. (approx.): 61 BTU/Hr.
Input
Input 115VAC 60Hz rated @ 2.6A.
Power supply input options:
a) One (1) common power input for ACM8/ACM8CB and lock power (factory installed).
b) Two (2) isolated power inputs – One (1) to power the ACM8/ACM8CB and one (1) for lock accessory power, (external power supply is required). (Current is determined by the power supply connected, not to exceed a maximum of 10A total).
Eight (8) Access Control System trigger inputs.
Input options:
a) Eight (8) normally open (NO) inputs.
b) Eight (8) open collector inputs.
c) Any combination of the above.
Output
12VDC @ 10A supply current.
ACM8 board main fuse is rated at 10A.
Eight (8) independently controlled outputs.
Output options:
Eight (8) Fail-Safe and/or Fail-Secure power outputs.
Eight (8) auxiliary power outputs (unswitched).
Output ratings
PTCs are rated @ 2.5A.
Filtered and electronically regulated outputs (built-in power supply).
Supervision
A