Browse Categories

Altronix T1VK3F4 4-Door Altronix/HID VertX® Access and Power Integration Kit - Trove1V1 with eFlow6NB, VR6, PDS8

Item #: AL-T1VK3F4

Product Info

ALT1VK3F4
ALTRONIX CORPORATION
T1VK3F4

TROVE1V1 12/24VDC@6A FUSED

Altronix T1VK3F4 kit consists of Trove1 enclosure, TV1 VertX®/Altronix backplane with one (1) 12 or 24VDC @ 6A power supply/charger, one (1) voltage regulator and one (1) dual input fused power distribution module. ?This kit also accommodates up to two (2) HID VertX® modules for up to four (4) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.

eFlow6NB Power Supply/Charger
Input
Voltage: 120VAC, 60Hz, 3.5A max.
Fusing: 5A / 250V.
Outputs
Voltage: 12VDC or 24VDC selectable.
Current: 6A continuous max.
Auxiliary: Power-limited @ 1A (unswitched).
Other: Overvoltage protection. Filtered and regulated.
Battery Charging
Capacity: 7AH/12VDC (2 within enclosure); 40AH/65AH (requires separate enclosure)
Type: Sealed lead acid or gel type
Failover: Upon AC loss, instantaneous
(Batteries are sold separately).
Fire Alarm Disconnect
Supervised: Latching or non latching.
EOL: 10K Resistor.
Supervision
AC Failure: Form “C” contacts.
Battery: Form “C” contacts.
Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
Indicators LED
Input: 120VAC is present.
DC Output: Powered.
ACM4 Access Power Controller
Input
Voltage: 24VDC from eFlow6NB
Input Fuse: 10A /32V
Outputs
Voltage: 24VDC
Four (4) independently controlled fused outputs:
a) Fail-Safe and/or Fail-Secure power outputs
Form “C” Relays rated 28VAC or VDC @ 2.5A
b) Auxiliary power outputs (unswitched)
c) Any combination of the above
Output Fuses: 3A/32V
Indicators (LED)
Red LEDs: Outputs are triggered (relays energized).
Green LED: FACP disconnect is triggered.
VR6 Voltage Regulator
Input
Voltage: 24VDC from eFlow6NB.
Output
Voltage: 12VDC.
Current: 6A continuous.
Other: Surge suppression.
Indicators LED
Input: 24VDC is present.
Output: Powered.
PDS8 Dual Input Power Distribution Module
Input
Voltage: 24VDC from eFlow6NB and 12VDC from VR6.
Main Fuse: 10A/32V.
Outputs
Voltage: 12VDC and/or 24VDC.
Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2.
Individual outputs may be set to OFF position for servicing.
Output Fuses: 3A/32V.
Indicators (LED)
DC Output: Eight (8) individual output LEDs.
Green: 12VDC
Red: 24VDC.
Environmental
Temperature
Operating: 0° C to 49° C (32° F to 120° F).
Storage: –

NOT IN STOCK
QTY:

Have Questions?

Ask our experts: