Browse Categories

Altronix T2KSK3F8 8-Door Altronix/Keri Systems Access and Power Integration Kit - Trove2KS2 with eFlow6NB, ACMS8, VR6, PDS8

Item #: AL-T2KSK3F8

Product Info

ALT2KSK3F8
ALTRONIX CORPORATION
T2KSK3F8

TROVE2KS2 8-DR 6A FUSE

Altronix T2KSK3F8 kit consists of Trove2 enclosure, TKS2 Keri Systems/Altronix backplane with one (1) 24VDC @ 6A power supply/charger, one (1) dual output fused access power controller, one (1) voltage regulator and one (1) dual input fused power distribution module.?This kit also accommodate various combinations of Keri Systems boards for up to eight (8) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.

eFlow6NB Power Supply/Charger
Input
Voltage: 120VAC, 60Hz, 3.5A max.
Main Fusing: 5A / 250V.
Output
Voltage: Factory set at 24VDC.
Current: 6A continuous.
Auxiliary: Class 2 power-limited @ 1A (unswitched).
Other: Overvoltage protection. Filtered and regulated.
Battery Charging
Capacity: 12AH/12VDC (2 within enclosure); 40AH/65AH (requires separate enclosure)
Type: Sealed lead acid or gel type
Failover: Upon AC loss, instantaneous.
(Batteries are sold separately).
Fire Alarm Disconnect
Supervised: Latching or non-latching.
EOL: 10K Resistor.
Supervision
AC Failure: Form “C” contacts.
Battery: Form “C” contacts.
Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. Prevents deep battery discharge.
Indicators LED
Input: 120VAC is present.
DC Output: Powered.
Battery: Discharged or not connected.
PDS8 Dual Input Power Distribution Module
Input
Voltage: 24VDC from eFlow6NB and 12VDC from VR6.
Main Fuse: 10A / 32V.
Outputs
Voltage: 12 or 24VDC individually selectable.
Output Fuses: 3A / 32VDC.
Indicators LED
DC Output: Eight (8) individual output LEDs.
Green: 12VDC
Red: 24VDC.
ACMS8 Dual Input Access Power Controller
Input
Voltage: 24VDC from eFlow6NB and 12VDC from VR6.
Input Fuse: 15A / 32V.
Outputs
Voltage: 12 or 24VDC individually selectable.
Eight (8) selectable 12VDC – 24VDC independently controlled outputs or eight (8) indepently controlled Form “C” relay outputs:
a) Fail-Safe and/or Fail-Secure power outputs.
b) Form “C” Relays. 28VAC or VDC @ 2.5A Rated.
c) Auxiliary power outputs (unswitched).
d) Any combination of the above.
Any of the eight (8) fuse protected power outputs are selectable to follow power Input 1 or Input 2.
Individual outputs may be set to OFF position for servicing.
Output Fuses: 3A / 32VDC.
Indicators LED
Red LEDs: Outputs are triggered (relays energized).
Blue LED: FACP disconnect is triggered.
Individual voltage LEDs:
Green: 12VDC
Red: 24VDC
VR6 Voltage Regulator
Input
Voltage: 24VDC fro