Napco StarLink MAX2 Fire Communicator
Product Info
Dual Carrier, Verizon and AT&T,Red Metal Enclosure,Powered by Control Panel Input: 10-27.5VDC Includes (4) EOLR Zone inputs for connection to legacy FACPs (2) Form C relay outputs, eliminating the need for additional listed supervision relay
The SLE-MAX2-CFB is a commercial dual path fire IP/cellular alarm communicator featuring dual carrier communication via Verizon and AT&T networks. Housed in a red metal enclosure, it complies with UL985 Household Fire Warning System and UL864 10th Edition Control Units for Fire Alarm Systems standards. Powered by the control panel, it includes (4) EOLR Zone inputs for legacy FACP connection and (2) Form C relay outputs for simplified installation.
Features:
Max Fire RMR for You & Less Operational Expenses for Them on ALL FACUs 12V/24V, using 5G LTE-M Cellular Fire Alarm Reporting vs. POTs Landlines
One High-Performance Model to Stock on Your Truck for Commercial Fire Communications: Both Verizon & AT&T plus either sole cell-only or dual path cell/IP reporting
Easy Automatic Cell Network-Select for Max Signal Strength & Easy ID Cell Indicators, Red (VZ) / Blue (AT&T) inside
See /Set SIM Status Remotely – using any PC or smart device
Faster, Simpler to Install, When Techs are Scarce; NO panel reprogramming,Quick-Connect FACU Modular Jacks, NO additional power supply
No Hidden Extra Costs: Self-Supervised, 4 EOLR inputs & 2 Form C-Outputs; Plus, 2 High-Performance Antennas Included
New Lower Cost, Lower Rates & Instant Rebate for Napco Pros – Nothing to send in
UL Listed End to End: UL 864 Listed StarLink FIre Communicator44 UL 864 Napco NY NOC w/ PA Failover44 Any Central Station’s UL Receiver
Specifications:
Electrical Ratings for +12V / 24V (Models w/o Power Supply)
Input Voltage – 10-24VDC regulated (power-limited output from UL Certified FACU/panel Aux/Remote Fire Power)
Input Current – 24VDC standby: 85mA
Electrical Ratings Fire Input 1
Input Voltage – 9-25VDC
Max Input Current – Up to 2mA from FACU NAC circuit
Electrical Ratings for Inputs 2 to 5 (Class B)
Maximum Loop Voltage – 25VDC
Maximum Loop Current – 1.2mA (metal models); 1.7mA (plastic)
End of Line Resistor (EOLR) Value – 10K
Electrical Ratings for PGM3 Output
Open Collector Output – Max Voltage 3V when active; 25V max. when not
PGM Max Sink Current – 50mA (up to 15VDC), 25mA (15.1VDC -25VDC)
Physical & Environmental
Plastic Housing – 8 × 5½ x 1½ ”(WHD) + antennas (2ea, supplied) 81/4” H
Metal Housing – 11½ x 9½ x 3½”(WHD) + antennas (2ea, supplied) 81/4” H
Housings – 2 Keyholes for wall mount
Operating Temp – 32 to 120°F , 93% Humidity Max
COMPLIANCES
NFPA 72 Eds: 2022, 2019, 2016, 2013, 2010; UL 2610, UL 985, UL1023, UL864 10th Ed., CSFM, NYC FD