Napco StarLink MAX2 Fire Communicator
Product Info
Dual Carrier, Verizon and AT&T,Metal Enclosure,120VAC Power Includes power provisions for backup battery/charger and (4) EOLR Zone inputs for connection to legacy FACPs (2) Form C relay outputs, eliminating the need for additional listed supervision relay
StarLink Fire Max 2 DUAL with Dual SIM card capability for Verizon and AT&T networks, it is a dual-path communicator for reliable cellular/IP connectivity. Includes a secure metal enclosure with locking mechanism and power supply. 5G LTE-M Network.
Features:
Max Fire RMR for You & Less Operational Expenses for Them on ALL FACUs 12V/24V, using 5G LTE-M Cellular Fire Alarm Reporting vs. POTs Landlines
One High-Performance Model to Stock on Your Truck for Commercial Fire Communications: Both Verizon & AT&T plus either sole cell-only or dual path cell/IP reporting
Easy Automatic Cell Network-Select for Max Signal Strength & Easy ID Cell Indicators, Red (VZ) / Blue (AT&T) inside
See /Set SIM Status Remotely – using any PC or smart device
Faster, Simpler to Install, When Techs are Scarce; NO panel reprogramming,Quick-Connect FACU Modular Jacks, NO additional power supply
No Hidden Extra Costs: Self-Supervised, 4 EOLR inputs & 2 Form C-Outputs; Plus, 2 High-Performance Antennas Included
New Lower Cost, Lower Rates & Instant Rebate for Napco Pros – Nothing to send in
UL Listed End to End: UL 864 Listed StarLink Fire Communicator44 UL 864 Napco NY NOC w/ PA Failover44 Any Central Station’s UL Receiver
Specifications:
Electrical Ratings for 120VAC, 60Hz (Models with Power Supply)
Input Voltage – 20VAC nominal
Input Current – 200mA maximum
Maximum Charging Current – 200mA
Electrical Ratings Fire Input 1
Input Voltage – 9-25VDC
Max Input Current – Up to 2mA from FACU NAC circuit
Electrical Ratings for Inputs 2 to 5 (Class B)
Maximum Loop Voltage – 25VDC
Maximum Loop Current – 1.2mA (metal models); 1.7mA (plastic)
End of Line Resistor (EOLR) Value – 10K
Electrical Ratings for PGM3 Output
Open Collector Output – Max Voltage 3V when active; 25V max. when not
PGM Max Sink Current – 50mA (up to 15VDC), 25mA (15.1VDC -25VDC)
Physical & Environmental
Plastic Housing – 8 × 5½ x 1½ ”(WHD) + antennas (2ea, supplied) 81/4” H
Metal Housing – 11½ x 9½ x 3½”(WHD) + antennas (2ea, supplied) 81/4” H
Housings – 2 Keyholes for wall mount
Operating Temp – 32 to 120°F , 93% Humidity Max
COMPLIANCES