DORMAKABA DELAYED EGRESS MAGLOCK WITH
Product Info
The DE8310 Delayed Egress all-in-one lock can detect when pressure is applied to a door and can be field selected with a release delay of 15 or 30 seconds. This perimeter door solution is unique in that there is no need to replace existing door hardware, making it an easy and affordable access solution. The RCI DE8310 includes an external alarm sounder, keyswitch for reset and override, and a building code sign for single outswinging doors. The RCI DE8310-S includes a built-in sounder rather than the external sounder in the base unit. This electromagnetic lock series can be monitored locally or remotely through relay outputs. It is ideal for applications requiring loss prevention, life safety, and traffic control.
Features
Built-in sensor detects when pressure is applied to outward swinging doors – no need to replace existing door hardware?Field-selectable 15 or 30 second release delay with field-selectable 0 to 3 second nuisance delay?Unique highly visible red/green light panel indicates status of door (local)?Includes 960 Keyswitch for reset and override, Building Code Sign and base unit (DE8310) includes a 914 External Sounder?Dry contact SPDT and DPDT relays provided for local and/or remote monitoring?Keyhole mounting for ease of installation?Convenient plug-in wiring harnesses?Easy-access wiring cavity?Stabilizing 4-bolt “drop stop” mounting?Surge protection
Specifications
Housing Dimensions2-1/8” (54mm) Deep x 2-7/8” (73mm) High Profile with10-13/16” (275mm) Length for the base unit
11-3/4” (299mm) Length with voice or sound options 14” (355mm) Length with camera and voice or sound options
This includes the 1/4” (6mm) mounting bracket.
Armature Plate Dimensions – 5/8“D x 2-3/8“H x 7-7/16“L (16mm x 60mm x 189mm)
Voltage – Auto sensing voltage 12 to 24 VDC Tolerance ±10%
Power/Current RequirementsCamera Unit – Max 0.79A@12VDC Max 0.39A@24VDC
Voice/Sounder Unit – Max 0.66A@12VDC Max 0.33A@24VDC
Base Unit with external sounder – Max 0.61A@12VDC Max 0.32A@24VDC
Holding Force – Up to 1200 lbs (540kg) pounds
Certification – cULus Listed GWXT Auxiliary Locks | Patent pending
cURus Component for use in FWAX Special Locking Arrangements
Operating Temperature – Not for use in outdoor environments. Circuit board operating temperature 14ºF to 140ºF (-10ºC to 60ºC)