ALULA Heat Detector
Product Info
The Alula RE617 is a Connect+ encrypted wireless heat detector that is compatible with the Alula Connect+ security system panel. The RE617 heat alarm is a fire-protection device that alarms when it detects temperatures above 135°F (57°C) or temperature changes greater than 15°F (8.3°C)/min and the temperature is above 104°F (40°C). The red LED on the alarm sensing heat flashes rapidly to indicate this is the alarm sensing heat/fire.
Fire authorities recommend you put individual smoke alarms in or near all rooms where fire is most likely to break out (apart from the locations to avoid e.g bathrooms). The living room is the most likely place for a fire to start at night, followed by the kitchen (where a heat alarm is recommended) and then the dining room. Consideration should be given to installing smoke alarms in any bedrooms where fires might occur, for instance, where there is an electrical appliance such as an electric blanket or heater, or where the occupant is a smoker. In addition, consideration should be also given to installing smoke alarms in any rooms where the occupant is unable to respond very well to a fire starting in that room, such as an elderly or sick person or a very young child.
Features:
Heat Detection
Wireless Connect+ encryption
UL539 and ULC-S530 listings
5 year warranty
Specifications:
Dimensions: 4.7 × 1.8 inches (12.0 × 4.6 centimeters)
Weight (with Batteries): 7.36 ounces (210 grams)
Mounting Fastener: #6 screws and anchors (provided)
Temperature Range: 40°F to 100°F (4.4°C to 37.8°C) Long-Term
Maximum Humidity: 15% to 95% non-condensing relative humidity
Frequency: 433.92 MHz
Replacement Batteries: Two Panasonic® CR123A
Transmitted Indications: Low Battery, Supervision
Loudness: 85 dBA at 10 feet (3m) minimum
Heat Sensor: 135 ± 5°F (57 ± 2°C) or Rate of Rise 15°F (8.3°C)/min & >104°F (40°C), 70ft spacing
Certification: FCC, IC, UL539, ULC-S530
For use in:
In all sleeping rooms and guest rooms
Outside of each separate dwelling unit sleeping area within 6.4 m (21 ft) of any door to a sleeping room, the distance measured along a path of travel
On every level of a dwelling unit, including basements
On every level of a residential board and care occupancy (small facility), including basements and excluding crawl spaces and unfinished attics
In the living area(s) of a guest suite
In the living area(s) of a residential board and care occupancy (small facility)