Browse Categories

ALTRONIX CORPORATION UL 24VDC@10A AC/BATT SUP MOM5OUT W/ENCL

Item #: AL-AL1024ULMR

Product Info

ALAL1024ULMR
ALTRONIX CORPORATION
AL1024ULMR

24VDC @ 10 AMP 115VAC INPUT AC AND BATTERY MONITORING. FIRE ALARM INTERFACE. FIVE (5) INDIVIDUALLY PTC PROTECTED CLASS 2 RATED POWER LIMITED OUTPUTS RED ENCLOSURE 15.5?H X 12?W X 4.5?D. UL/CUL LISTED (UL294) (UL1481). CSFM AND MEA APPROVED.

AL1024ULMR multi-output access control power supply/charger is specifically designed for use with access control systems and accessories.This unit converts a 115VAC, 60Hz input into five (5) individually protected Class 2 Rated power limited 24VDC outputs. Each output will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. These outputs will operate in both Fail-Safe and Fail-Secure modes. Controlled trigger input is achieved through normally open (N.O.) or normally closed (N.C.) supervised input or the polarity reversal from an FACP (Fire Alarm Control Panel). A form “C” dry output relay enables HVAC Shutdown, Elevator Recall or it may be used to trigger auxiliary devices.

Input
Input 115VAC, 60Hz, 4.2A.
Input fuse rated @ 3.5A/250V.
Fire Alarm Panel or Access Control System trigger inputs. N.O. or N.C. supervised trigger input and polarity reversal trigger input.
Output
24VDC outputs.
10A supply current.
Five (5) PTC protected Class 2 Rated power limited outputs, rated @ 2A (auto-resettable).
Output relay energizes when unit is triggered (form “C” contact rated 1A @ 28VDC).
Filtered and electronically regulated output.
Short circuit and thermal overload protection.
Battery Backup
Built-in charger for sealed lead acid or gel type batteries.
Automatic switch over to stand-by battery when AC fails.
Zero voltage drop when switching over to battery backup.
(Batteries are sold separately).
Supervision
AC fail supervision (form “C” contacts).
Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
Low battery supervision (form “C” contacts).
Battery presence supervision (form “C” contacts).
Power fail supervision relay (form “C” contacts).
Visual Indicators
AC input and DC output LED indicators (power supply board).
Red LEDs indicate condition of power outputs (multi-output board).
Power & input trigger LEDs (multi-output board).
Temperature
Operating: 0° C to 49° C (32° F to 120° F).
Storage: – 20° C to 70° C ( – 4° F to 158° F).
Relative Humidity 85% +/- 5%.
BTU/Hr (approx.): 123 BTU/Hr.
System AC input VA requirement: 483VA.
Enclosure:
Wall mount enclosure for indoor use.
Accommodates up to two (2) 12VDC/7AH Batteries.
Dimensions 12.25“W x 15.5“H x 4.5“D (311 mm W x 394 mm H x 114 mm D).
1.125” and 1.375” combination knockouts.
Weights (approximate):
Product Weight: 10.8 Lbs. (4.898 kg).
Shipping Weight: 11.8 Lbs. (5.352 kg).

IN STOCK
QTY:

Have Questions?

Ask our experts: