Search in Brand
Filter Your Search
Shop by Category
Shop POTTER ELECTRIC SIGNAL CO. | Brands We Sell
POTTER STROBE LIGHT;60K CANDLE POWER
The SL-401 is the lowest current consumption, weather-proof strobe in its class. It operates on 12V DC and draws a low 115mA. It is made of high impact resistant thermoplastic to stand up to abuse. The strobe is rated at 60,000 candle power and is designed with an operating life in excess of 200 hours of continuous operation.
POTTER HEAT DETECTOR FIXED/ROR 200
The CR Series detectors are combination Rate-of-Rise and Fixed Temperature. The Rate-of-Rise function allows the detector to operate when the temperature at the detector increases at a rate of 15°F per minute. The Fixed Temperature portion will cause the detector to operate when it reaches the applicable temperature. The Rate-of-Rise portion of the detector is restorable; however the Fixed Temperature portion is non-restorable.
POTTER PRESSURE SUPERVISORY SWITCH
The Potter PS40 Series Supervisory Pressure Actuated Switches are designed primarily to detect an increase and/or decrease from normal system pressure in automatic fire sprinkler systems. Typical applications are: air/nitrogen supervision in dry pipe and pre-action systems, pressure tanks, air supplies, and water supplies. The PS40-1 has one switch and is factory set to activate at approximately 30 psi (2,1 bar) on a decrease in pressure. The PS40-2 has two switches. The Low switch is factory set to activate at approximately 30 psi (2,1 bar) on a decrease in pressure. The High switch is factory set to activate at approximately 50 psi (3,5 bar) on an increase in pressure. NFPA 72 requires a supervisory signal if the pressure increases or decreases by 10 psi from normal. The PS40 is factory set for a normal air pressure of 40 psi.
POTTER SIGNALINK WIRELESS REPEATER
The repeater can be powered by one 3.6 volt D size Lithium Thionyl battery or by the auxiliary power of the fire panel or UL 864 or UL 1481 listed 24 VDC supply with battery backup. See ordering information on page 10 for optional power supply. Per UL 864, if the repeater is powered by batteries it must be dedicated to only one transmitter repeater pair. If the repeater is powered by a listed supply it can support multiple transmitters. The device includes a cover tamper, pry-off tamper switch, an LED to indicate when it is transmitting, and an LED to aid in resetting the battery meter.
POTTER MECH CONTACT NO/NC GRAY
The AMS-38 Mechanical Surface Mount Contact is a UL listed and AC rated contact designed to endure higher voltages than other standard reed contact switches. The AMS-38 can be used to protect openings or to activate other applications such as lighting, sounders, or any other secondary function.
POTTER CONTACT,OVERHEAD DOOR,2"GAP,
The ODC-59 Series Overhead Door Contacts are exclusively designed for rugged high traffic installations. The reed switch is hermetically sealed with a PVC shock absorber enclosed within a solid aluminum housing. Installation wires are protected in a 24” stainless steel armored cable. The ODC-59 Series magnet is mounted on an adjustable L shaped bracket designed for greater flexibility, universal mounting, greater pulling power, and to provide a professional installation appearance.
POTTER SLC EXPANDER FOR PFC
The Signaling Line Circuit Expander (SLCE-127) allows for an additional loop for the PFC-6200 and up to seven additional loops for PFC-6800 fire alarm control panels. Each loop adds 127 addressable sensors or modules in any combination. The SLCE-127 may be configured for Class A or Class B wiring without the need for additional modules. The SLCE-127 communicates with the control panel via the Potter P-Link communication bus. The loop adder is mounted in either the control panel cabinet, the intelligent power supply/P-Link repeater, the PSN-1000E, AE-8 or the AE-14 expander cabinet. Each card is mounted to the exclusive Stacker Bracket for secure and accessible mounting.
POTTER FIXED TEMP 200'F MOISTUREPROOF
The MP Series is a standard THERMOFLEX® single circuit, Normally Open contacts detectors, in which the connectivity is modified with pigtail leads that extend through a seal plate.This provides for enhanced protection against corrosive or moisture-laden environments. This model is a fixed temperature only detector and should be installed in areas where rapid fluctuations in ceiling temperatures are expected.
This detector is suitable for use in areas where condensation or corrosion can have harmful effects on circuit wiring connected to standard terminals. Its seal plate (with extended pigtail leads) will mount onto a typical cast exterior back box.The detector is connected to a fire alarm system’s input circuit as an initiating device.The internal contacts are normally open, and will close when the detector operates either on a rate of temperature increase, or if the releasing temperature is reached.
POTTER HOLD-UP SWITCH W/ RESET TOOL
The HUS-7A is a single button, latching hold-up switch designed to provide a rapid signal to alarm systems. It is activated by pressing down the single button switch.
A status window indicates the condition of the switch: RED (alarmed), BLUE (armed).?A U-shaped key is supplied to reset the HUS-7A.?The hold-up switch sends a signal to a dedicated 24 hour hold-up circuit of a burglar control panel.
POTTER 120VAC HORN/STROBE RED
The SH-120 Series Horn Strobe is designed to provide audible and/or visual signals for fire and burglar alarm protection systems and notification signals for the purpose of life safety and protection.
The SH-120 are operable with a 120 VAC system between 96 VAC and 132 VAC. They can be interfaced with pull stations, flow switches, and sprinkler systems for residential, commercial and industrial applications.
The SH Series combines a selective three horn tone and provides a continuous tone or temporal pattern (code 3) when constant voltage is applied. This SH-120R features a red housing and a clear lens.